Evaluation of Different Polishing Systems and Speeds for Dental Zirconia.
Chavali R
,
Lin CP
,
Lawson NC
.
???displayArticle.abstract???
PURPOSE: To evaluate two polishing systems and three polishing speeds on the gloss, roughness, and heat production of yttria stabilized tetragonal zirconia polycrystal (Y-TZP).
MATERIALS AND METHODS: A Y-TZP block (Zenostar Zr Translucent) was sectioned into 4-mm-thick sections. Specimens (n = 30 per polishing system) were first wet ground with a fine diamond bur at 200,000 RPM for 15 seconds. The baseline gloss of all specimens was measured in a glossmeter (60° angle) in a direction perpendicular to grinding. Initial surface roughness (Ra ) was determined on an optical profilometer in a direction perpendicular to grinding. The specimens were then polished with either a Dialite ZR Polishing Kit or a CeraMaster Polishing Kit. All grinding and polishing was performed by the same operator calibrated to apply approximately 2 N pressure. The medium grit polisher was used for 30 seconds, repeated for 30 seconds, and then the fine grit polisher was used. After each step, the gloss and roughness of each specimen was remeasured as described previously. Each polishing system was used at 5000, 15,000, and 40,000 RPM (n = 10 for each polish system/speed combination). A group of glazed specimens (n = 10) was evaluated for gloss and roughness as a control. The heat generated for each polishing step was measured with a thermocouple. The gloss and roughness of the specimens were analyzed using a linear mixed model and Tukey-Kramer post-hoc tests. Each step of polishing was compared to the glazed control group with an ANOVA and Dunnett''s test.
RESULTS: Polishing step, system, and speed were significant (p < 0.05) for gloss and roughness. Examination of system and step interaction was significant for gloss only. Post-hoc analysis revealed that 15,000 RPM produced higher gloss and lower roughness than other speeds. Each progressive step produced an improvement in gloss except for initial 30 seconds with the CeraMaster Coarse (medium polisher; p = 0.34). Roughness was also reduced at each progressive step. No polishing speed/system produced an increase in temperature above 41°C. Both polishing systems were capable of achieving a similar or superior roughness and gloss as the glazed control specimens after the final polishing step at 15,000 RPM.
CONCLUSIONS: Fifteen thousand RPM is an optimal polishing speed. Progressing through the polishing sequence significantly improves gloss and roughness and can create similar values as glazed zirconia.
Aboushelib,
Effect of surface treatment on flexural strength of zirconia bars.
2010, Pubmed
Aboushelib,
Effect of surface treatment on flexural strength of zirconia bars.
2010,
Pubmed
Baldissara,
Clinical and histological evaluation of thermal injury thresholds in human teeth: a preliminary study.
1997,
Pubmed
Chadwick,
The perception of gloss: a review.
2015,
Pubmed
Curtis,
The influence of surface modification techniques on the performance of a Y-TZP dental ceramic.
2006,
Pubmed
Denry,
Microstructural and crystallographic surface changes after grinding zirconia-based dental ceramics.
2006,
Pubmed
Denry,
Effect of heat treatment after accelerated aging on phase transformation in 3Y-TZP.
2010,
Pubmed
Dupriez,
A comparative study of sliding wear of nonmetallic dental restorative materials with emphasis on micromechanical wear mechanisms.
2015,
Pubmed
Goldstein,
Profilometer, SEM, and visual assessment of porcelain polishing methods.
1991,
Pubmed
Guazzato,
Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic.
2005,
Pubmed
Guess,
All-ceramic systems: laboratory and clinical performance.
2011,
Pubmed
Happe,
Effects of different polishing protocols on the surface roughness of Y-TZP surfaces used for custom-made implant abutments: a controlled morphologic SEM and profilometric pilot study.
2015,
Pubmed
Işeri,
Comparison of different grinding procedures on the flexural strength of zirconia.
2012,
Pubmed
Janyavula,
The wear of polished and glazed zirconia against enamel.
2013,
Pubmed
Jones,
The in vivo perception of roughness of restorations.
2004,
Pubmed
Kelly,
Stabilized zirconia as a structural ceramic: an overview.
2008,
Pubmed
Kosmac,
The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic.
1999,
Pubmed
Lawson,
Wear of enamel opposing zirconia and lithium disilicate after adjustment, polishing and glazing.
2014,
Pubmed
Lefever,
Laboratory evaluation of the effect of toothbrushing on surface gloss of resin composites.
2014,
Pubmed
Mörmann,
Wear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and Martens hardness.
2013,
Pubmed
Patterson,
Efficacy of a porcelain refinishing system in restoring surface finish after grinding with fine and extra-fine diamond burs.
1992,
Pubmed
Pereira,
Effect of grinding with diamond-disc and -bur on the mechanical behavior of a Y-TZP ceramic.
2014,
Pubmed
Preis,
Surface properties of monolithic zirconia after dental adjustment treatments and in vitro wear simulation.
2015,
Pubmed
Preis,
The effectiveness of polishing kits: influence on surface roughness of zirconia.
2015,
Pubmed
Quirynen,
The influence of surface free energy and surface roughness on early plaque formation. An in vivo study in man.
1990,
Pubmed
Subaşı,
Mechanical properties of zirconia after different surface treatments and repeated firings.
2014,
Pubmed
Teughels,
Effect of material characteristics and/or surface topography on biofilm development.
2006,
Pubmed
Wang,
Surface roughness of a novel dental porcelain following different polishing procedures.
2009,
Pubmed
,
Echinobase
Willems,
The surface roughness of enamel-to-enamel contact areas compared with the intrinsic roughness of dental resin composites.
1991,
Pubmed
Wright,
Comparison of three systems for the polishing of an ultra-low fusing dental porcelain.
2004,
Pubmed
ZACH,
PULP RESPONSE TO EXTERNALLY APPLIED HEAT.
1965,
Pubmed